Related Topics - HVAC diagramming, Loop Diagrams, Component Shapes, Stencils
Stencil Component Shapes - Zone HVAC Groups, Air Loop
The hyperlinks within the first column go to the Simergy component description, while the IDD Object within EnergyPlus is defined on the right side.
Simergy Component Shape | EnergyPlus IDD Object |
Absorption Chiller Heater | ChillerHeater:Absorption:DirectFired |
Chiller | Chiller:ConstantCOP |
CHW Headered Pumps-2 | HeaderedPumps:ConstantSpeed |
CHW Headered Pumps-3 | HeaderedPumps:ConstantSpeed |
CHW Headered VSD Pumps-2 | HeaderedPumps:VariableSpeed |
CHW Headered VSD Pumps-3 | HeaderedPumps:VariableSpeed |
District Clg | DistrictCooling |
Ground Heat Exchanger Pond_CHW | GroundHeatExchanger:Pond |
Ground Heat Exchanger Surface_CHW | GroundHeatExchanger:Surface |
Ground Heat Exchanger Vertical_CHW | GroundHeatExchanger:Vertical |
HeatX Hydronic_CHW | HeatExchanger:Hydronic |
HeatX Waterside Economizer_CHW | HeatExchanger:WatersideEconomizer |
Pump LtR CHW | Pump:ConstantSpeed |
Pump RtL CHW | Pump:ConstantSpeed |
Pump VSD LtR CHW | Pump:VariableSpeed |
Pump VSD RtL CHW | Pump:VariableSpeed |
Vapor Compression Chiller (CHW) | Chiller:EngineDriven |
Vapor Compression Chiller (Air) | Chiller:EngineDriven |
HP Wtr to Wtr Clg (CHW) | HeatPump:WaterToWater:EquationFit:Cooling |
Tempering Valve | TemperingValve |
Thermal Storage Mixed | ThermalStorage:ChilledWater:Mixed |
Thermal Storage Stratified | ThermalStorage:ChilledWater:Stratified |
Thermal Storage Ice | ThermalStorage:Ice:Simple |
Non-Return Valve | |
Splitter | Connector:Splitter |
Mixer | Connector:Mixer |
Simergy Component Shape | EnergyPlus IDD Object |
Coil Group | |
Air Terminal Group | |
Zone Equipment Group | |
Grp-Cooling Coil 2-Port | Coil:Cooling:Water |
Grp-HX Assisted Cooling Coil | CoilSystem:Cooling:Water:HeatExchangerAssisted |
Radiant Cool Beam Active_cool | AirTerminal:SingleDuct:ConstantVolume:CooledBeam |
Radiant Cool Beam Passive_cool | AirTerminal:SingleDuct:ConstantVolume:CooledBeam |
4-Pipe Induction Active_heatcool | AirTerminal:SingleDuct:ConstantVolume:FourPipeInduction |
4-Pipe Induction Passive_heatcool | AirTerminal:SingleDuct:ConstantVolume:FourPipeInduction |
4-pipe fan coil unit_sm | ZoneHVAC:FourPipeFanCoil |
Radiant Clng (CHW) | ZoneHVAC:LowTemperatureRadiant:VariableFlow |
Radiant Floor (CHW) | ZoneHVAC:LowTemperatureRadiant:VariableFlow |
Unit Ventilator | ZoneHVAC:UnitVentilator |
HP Wtr to Air (CHW) | AirLoopHVAC:UnitaryHeatPump:WaterToAir |
Unitary HP Water to Air_CHW | ZoneHVAC:WaterToAirHeatPump |
Furnace (heat/cool) (CHW) | AirLoopHVAC:Unitary:Furnace:HeatCool |
Unitary (heat-cool) (CHW) | AirLoopHVAC:UnitaryHeatCool |
Unitary Cool (CHW) | AirLoopHVAC:UnitaryCoolOnly |
Unitary heat cool w/ VAV bypass (CHW) | AirLoopHVAC:UnitaryHeatCool:VAVChangeoverBypass |
Simergy Component Shape | EnergyPlus IDD Object |
HvacHotWaterSupply | |
HvacHotWaterDemand | |
HvacControl | |
Boiler | Boiler:HotWater |
District Htg | DistrictHeating |
Ground Heat Exchanger Pond_HW | GroundHeatExchanger:Pond |
Ground Heat Exchanger Surface | GroundHeatExchanger:Surface |
Ground Heat Exchanger Vertical_HW | GroundHeatExchanger:Vertical |
Heat Pump Water Heater | WaterHeater:HeatPump |
HP Wtr to Wtr Htg (HW) | HeatPump:WaterToWater:EquationFit:Heating |
HW Headered Pumps-2 | HeaderedPumps:ConstantSpeed |
HW Headered Pumps-3 | HeaderedPumps:ConstantSpeed |
HW Headered VSD Pumps-2 | HeaderedPumps:VariableSpeed |
HW Headered VSD Pumps-3 | HeaderedPumps:VariableSpeed |
HW Heater | WaterHeater:Mixed |
Electric HW Heater | WaterHeater:Mixed |
Pump LtR HW | Pump:ConstantSpeed |
Pump RtL HW | Pump:ConstantSpeed |
Pump VSD LtR HW | Pump:VariableSpeed |
Pump VSD RtL HW | Pump:VariableSpeed |
Tempering Valve | TemperingValve |
Splitter | Connector:Splitter |
Mixer | Connector:Mixer |
Simergy Component Shape | EnergyPlus IDD Object |
Coil Group | |
Zone Equipment Group | |
Air Terminal Group | |
Grp-Heating Coil 2 Port | Coil:Heating:Water |
Grp-Pre-Heat Coil 2 Port | Coil:Heating:Water |
Finned Tube Radiator | ZoneHVAC:Baseboard:RadiantConvective:Water |
4-Pipe Induction Active_heatcool | AirTerminal:SingleDuct:ConstantVolume:FourPipeInduction |
4-Pipe Induction Passive_heatcool | AirTerminal:SingleDuct:ConstantVolume:FourPipeInduction |
Radiant Clng (HW) | ZoneHVAC:LowTemperatureRadiant:VariableFlow |
Radiant Floor (HW) | ZoneHVAC:LowTemperatureRadiant:VariableFlow |
Unit Heater (HW) | ZoneHVAC:UnitHeater |
Packaged Terminal AC | ZoneHVAC:PackagedTerminalAirConditioner |
Unit Ventilator | ZoneHVAC:UnitVentilator |
4-pipe fan coil unit_sm | ZoneHVAC:FourPipeFanCoil |
Grp-CV Term w/ reheat | AirTerminal:SingleDuct:ConstantVolume:Reheat |
Grp-VAV w/ reheat | AirTerminal:SingleDuct:VAV:Reheat |
Grp-VAV SeriesPIU w/reheat | AirTerminal:SingleDuct:SeriesPIU:Reheat |
Grp-VAV Vrble Spd Fan w/reheat | AirTerminal:SingleDuct:VAV:Reheat:VariableSpeedFan |
Grp-PIU-VAV htg coil | AirTerminal:SingleDuct:ParallelPIU:Reheat |
Absorption Chiller | Chiller:Absorption |
Absorption Chiller Heater | ChillerHeater:Absorption:DirectFired |
Absorption Chiller Heater - Air | ChillerHeater:Absorption:DirectFired |
HP Wtr to Air (HW) | AirLoopHVAC:UnitaryHeatPump:WaterToAir |
Unitary HP Wtr to Air (HW) | ZoneHVAC:WaterToAirHeatPump |
Furnace (heat/cool) (HW) | AirLoopHVAC:Unitary:Furnace:HeatCool |
Furnace (heat) (HW) | AirLoopHVAC:Unitary:Furnace:HeatOnly |
Unitary heat (HW) | AirLoopHVAC:UnitaryHeatOnly |
Unitary (heat-cool) (HW) | AirLoopHVAC:UnitaryHeatCool |
Unitary heat cool w/ VAV bypass (HW) | AirLoopHVAC:UnitaryHeatCool:VAVChangeoverBypass |
Simergy Component Shape | EnergyPlus IDD Object |
HvacCondenserSupply | |
HvacCondenserDemand | |
HvacControl | |
Pump VSD LtR CW | Pump:VariableSpeed |
Pump VSD RtL CW | Pump:VariableSpeed |
Cooling Tower | CoolingTower:SingleSpeed |
CW Headered Pumps-2 | HeaderedPumps:ConstantSpeed |
CW Headered Pumps-3 | HeaderedPumps:ConstantSpeed |
CW Headered VSD Pumps-2 | HeaderedPumps:VariableSpeed |
CW Headered VSD Pumps-3 | HeaderedPumps:VariableSpeed |
HeatX_CW | HeatExchanger:Plate |
Evaporative Fluid Cooler | EvaporativeFluidCooler:SingleSpeed |
Fluid Cooler | FluidCooler:SingleSpeed |
Pump LtR CW | Pump:ConstantSpeed |
Pump RtL CW | Pump:ConstantSpeed |
Splitter | Connector:Splitter |
Mixer | Connector:Mixer |
Simergy Component Shape | EnergyPlus IDD Object |
Coil Group | |
Air Terminal Group | |
Absorption Chiller_CW | Chiller:Absorption |
Absorption Chiller Heater_CW | ChillerHeater:Absorption:DirectFired |
Chiller_CW | Chiller:ConstantCOP |
HeatX_CW | HeatExchanger:Plate |
HeatX Hydronic_CW | HeatExchanger:Hydronic |
HeatX Waterside Economizer_CW | HeatExchanger:WatersideEconomizer |
Vapor Compression Chiller (CW) | Chiller:EngineDriven |
HP Wtr to Wtr Clg (CW) | HeatPump:WaterToWater:EquationFit:Cooling |
HP Wtr to Wtr Htg (CW) | HeatPump:WaterToWater:EquationFit:Heating |
Simergy Component Shape | EnergyPlus IDD Object |
HvacMixedWaterSupply | |
HvacMixedWaterDemand | |
HvacControl | |
Pump LtR (MxW) | Pump:ConstantSpeed |
Pump RtL (MxW) | Pump:ConstantSpeed |
Pump VSD LtR (MxW) | Pump:VariableSpeed |
Pump VSD RtL (MxW) | Pump:VariableSpeed |
MxW Headered Pumps-2 | HeaderedPumps:ConstantSpeed |
MxW Headered Pumps-3 | HeaderedPumps:ConstantSpeed |
MxW Headered Pumps-2 (VSD) | HeaderedPumps:VariableSpeed |
MxW Headered Pumps-3 (VSD) | HeaderedPumps:VariableSpeed |
Boiler | Boiler:HotWater |
Cooling Tower | CoolingTower:SingleSpeed |
Ground Heat Exchanger Pond (MxW) | GroundHeatExchanger:Pond |
Ground Heat Exchanger Surface (MxW) | GroundHeatExchanger:Surface |
Ground Heat Exchanger Vertical (MxW) | GroundHeatExchanger:Vertical |
Tempering Valve | TemperingValve |
Splitter | Connector:Splitter |
Mixer | Connector:Mixer |
Evaporative Fluid Cooler (MxW) | EvaporativeFluidCooler:SingleSpeed |
Evaporative Fluid Cooler (MxW) | EvaporativeFluidCooler:TwoSpeed |
HeatX (MxW) | HeatExchanger:Plate |
Fluid Cooler (MxW) | FluidCooler:SingleSpeed |
Fluid Cooler (MxW) | FluidCooler:TwoSpeed |
Simergy Component Shape | EnergyPlus IDD Object |
Coil Group | |
Air Terminal Group | |
Zone Equipment Group | |
HP Wtr to Air (MXW) | AirLoopHVAC:UnitaryHeatPump:WaterToAir |
Grp-Unitary HP MxW/MxW to Air (MxW) | ZoneHVAC:WaterToAirHeatPump |
Grp-Unitary HP MxW/CHW to Air (MxW) | ZoneHVAC:WaterToAirHeatPump |
Grp-Unitary HP MxW/HW to Air (MxW) | ZoneHVAC:WaterToAirHeatPump |
Grp-MxW Cooling Coil 2-Port | Coil:Cooling:Water |
______________________________________________________________________________________
© Copyright 2013 Simergy, Sustainable IQ, Inc.