Water Loop System Parameters

Workspace:  Systems/ Water Loops/Create-Edit

The Water Loop Parameters table establishes settings for the overall Water Loop performance.  The table is composed of two sets of columns that contain Properties, Values and Units.  Each water loop type has slight variations on either parameters included or default value options, so the parameters for the four different water types are listed below.

 

Condenser Water Loop Parameters

Maximum Loop Temperature

Manual Value Entry

Maximum Loop Flow Rate

Manual Value Entry or the option to select from the drop down list of default values (0-Minimum, Autosize)

Condenser Loop Volume

Select from drop down list for Auto-calculate or 0-Minimum

Pressure Simulation Type

Select from drop down list - None, Loop Flow Correction, Pump Power Correction.

Minimum Loop Temperature

Manual Value Entry

Minimum Loop Flow Rate

Manual Value Entry

Load Distribution Scheme

Select from drop down list - Sequential or Optimal

Sizing

Select from drop down list of available Source Library, Library Entries.

 

Chilled Water Loop Parameters

Maximum Loop Temperature

Manual Value Entry

Maximum Loop Flow Rate

Manual Value Entry or the option to select from the drop down list of default values (0-Minimum, Autosize)

Plant Loop Volume

Select from drop down list for Auto-calculate or 0-Minimum

Plant Loop Demand Calculation

Select from drop down list of available Source Library, Library Entries.

Sizing

Select from drop down list of available Source Library, Library Entries.

Pressure Simulation Type

Select from drop down list - None, Loop Flow Correction, Pump Power Correction.

Minimum Loop Temperature

Manual Value Entry

Minimum Loop Flow Rate

Manual Value Entry

Load Distribution Scheme

Select from drop down list - Uniform, Sequential or Optimal

Pressure Simulation Type

Select from drop down list of available Source Library, Library Entries.

 

Hot Water Loop Parameters

Maximum Loop Temperature

Manual Value Entry

Maximum Loop Flow Rate

Manual Value Entry or the option to select from the drop down list of default values (0-Minimum, Autosize)

Plant Loop Volume

Select from drop down list for Auto-calculate or 0-Minimum

Plant Loop Demand Calculation

Select from drop down list of available Source Library, Library Entries.

Sizing

Select from drop down list of available Source Library, Library Entries.

Pressure Simulation Type

Select from drop down list - None, Loop Flow Correction, Pump Power Correction.

Minimum Loop Temperature

Manual Value Entry

Minimum Loop Flow Rate

Manual Value Entry

Load Distribution Scheme

Select from drop down list - Uniform, Sequential or Optimal

Pressure Simulation Type

Select from drop down list of available Source Library, Library Entries.

 

Mixed Water Loop Parameters

Maximum Loop Temperature

Manual Value Entry

Maximum Loop Flow Rate

Manual Value Entry or the option to select from the drop down list of default values (0-Minimum, Autosize)

Plant Loop Volume

Select from drop down list for Auto-calculate or 0-Minimum

Plant Loop Demand Calculation

Select from drop down list of available Source Library, Library Entries.

Sizing

Select from drop down list of available Source Library, Library Entries.

Pressure Simulation Type

Select from drop down list - None, Loop Flow Correction, Pump Power Correction.

Minimum Loop Temperature

Manual Value Entry

Minimum Loop Flow Rate

Manual Value Entry

Load Distribution Scheme

Select from drop down list - Uniform, Sequential or Optimal

Pressure Simulation Type

Select from drop down list of available Source Library, Library Entries.

 

______________________________________________________________________________________