Libraries - Plant Equipment

Location = Libraries/Plant and Equipment/Plant Equipment

 

Type and Sub Type Mapping

The Type and Sub Type options that can be selected from the drop down lists in that area of the workspace, which filter the Source Library to display the variables the user can select to include, along with a value, in a Library Entry.

Note: The links within the table are to the EnergyPlus Input Output Reference and the explanations of the objects.

 

Type Options Sub Type Options EnergyPlus Objects (IO Reference links)

Solar Device

Solar Thermal Water

Solar PhotoVoltaic Thermal

Solar CollectorIntegralCollectorStorage

Solar Thermal Air

Solar Thermal Air Multisystem

SolarCollector:FlatPlate:ThermalWater

SolarCollector:FlatPlate:PhotoVoltaicThermal

SolarCollector:IntegralCollectorStorage

SolarCollector:UnglazedTranspired

SolarCollector:UnglazedTranspired:Multisystem

Boiler

Boiler Hot Water
Boiler Steam

Boiler:Hot Water

Boiler:Steam

Chiller

ChillerVaporCompressionElectric_EIR

ChillerVaporCompressionElectric_ReformulatedEIR

ChillerVaporCompressionElectric

ChillerVaporCompressionConstantCOP

ChillerVaporCompressionEngineDriven

ChillerVaporCompressionCombustionTurbine

AbsorptionIndirect

Absorbtion

Chiller:Electric:EIR

Chiller:Electric:ReformulatedEIR

Chiller:Electric

Chiller:ConstantCOP

Chiller:EngineDriven

Chiller:CombustionTurbine

Chiller:Absorption:Indirect

Chiller:Absorption

Chiller Heater

AbsorptionDirectFired
AbsorptionChillerDoubleEffect

ChillerHeater:Absorption:DirectFired

 

Heat Pump

WaterToWater_EquationFit_Heating

WaterToWater_EquationFit_Cooling

WaterToWater_ParameterEstimation_Cooling

WaterToWater_ParameterEstimation_Heating

HeatPump:WaterToWater:EquationFit:Heating

HeatPump:WaterToWater:EquationFit:Cooling

HeatPump:WaterToWater:ParameterEstimation:Cooling

HeatPump:WaterToWater:ParameterEstimation:Heating

Cooling Tower

SingleSpeed

TwoSpeed

VariableSpeed

VariableSpeed_Merkel

CoolingTower:SingleSpeed

CoolingTower:TwoSpeed

CoolingTower:VariableSpeed

 

 

Boiler (Type)

Boiler Steam (Sub Type)

 

Fuel Type

Maximum Operating Pressure

Theoretical Efficiency

design Outlet Steam Temperature

Nominal Capacity A/S

Minimum Part Load Ratio

Maximum Load Part Ratio

Optimum Load Part ratio

Coefficient of Fuel Use Function of Part Load ration Curve [1-3]

Sizing Factor

 

Solar Device (Type)

Solar Thermal Water (Sub Type)

 

Maximum Flow Rate

Gross Area

Test Fluid

Test Flow Rate

Test Correlation Type

Coefficient of Efficiency Equation [1-3]

Coefficient of Incident Angle Modifier [2-3]

 

 

Chiller (Type)

Absorption (Sub Type)

 

Nominal Capacity A/S

Nominal Pumping Power A/S

Minimum Part Load Ratio

Maximum Part Load Ratio

Optimum Part Load Ratio

Design Condenser Inlet Temperature

Design Chilled Water Flow Rate A/S

Design Condenser Water Flow Rate A/S

Coefficient of the Hot Water or Steam Use Part Load Ration Curve [1-3]

Chilled Water Outlet Temperature Lower Limit

Chiller Flow Mode

Generator Heat Source Type

Design Generator Fluid Flow Rate A/S

Degree of Subcooling in Steam Generator

Sizing Factor

 

 